MILK AMYLOID A

BIOMARKER FOR THE EARLY DIAGNOSIS OF MASTITIS AND FOR REDUCING THE USE OF ANTIBIOTICS.
5

Technical studies

Type of milk MAA Threshold SCC Threshold Sensitivity Specificity Type of mastitis Reference
Quarter >16,4mg/L 90,6% 98,3% Subclinical Safi et al. 2009
Quarter >130 89,6% 72,0% Subclinical Safi et al. 2009
Composite 100 96,6% 57,9% Major pathogen Jaeger et al. 2016
Composite 3,9μg/mL 84,7% 96,6% Major pathogen Jaeger et al. 2016
Composite 3,9μg/mL 100 82,0% 98,0% Major pathogen Jaeger et al. 2016
Tank 20,78 ng/mL <200> 97,3% 46,7% Subclinical Taghdiri, 2018

Two kit formats are available depending on the analytical needs of the laboratory:

  • TM-900 kit for 800 tests,
  • TP-8072 kit for 80 tests.
5

Milk Amyloid-A assay - a powerful early biomarker of mastitis

Milk Amyloid A (MAA) is an Acute Phase Protein biomarker specific to clinical and subclinical mastitis. MAA has been extensively evaluated and is now considered a better alternative to existing methods for the early diagnosis of mastitis in Dairy Herd Improvement testing program.

Based on an ELISA method, the MAA kits are designed to determine the amount of Amyloid A in raw milk in order to make an early diagnosis of mastitis, thus preserving animal welfare, improving milk production and reducing the use of antibiotics.

5

Advantages of MAA

Commonly used methods for the diagnosis of mastitis are somatic cell counts in milk or other types of bacteriological tests. However, these methods are not sufficiently effective for the diagnosis of mastitis:

  • In some cases, there is no bacterial growth despite the presence of infections (Koivula et al, 2007; Riekerink et al, 2008).
  • Negative results are common, especially if tests are done only once.
  • Possible bacterial contamination during sampling.

In contrast to these methods, the MAA assay provides earlier and more certain screening for udder infections:
 

  • MAA levels in healthy quarters are low or undetectable and increased rapidly in infected quarters of the same udder (Eckersall et al. 2001; Grönlund et al. 2003; Alsemgeest et al. 1994; Werling et al. 1996; Heegard et al. 2000; Hany Ahmed Hussein et al. 2018).
  • MAA levels can rapidly increase even up to 1000-fold following experimentally induced udder infection with E. Coli (Suojala et al., 2008), S.Aureus (Grönlund et al., 2003), Strep. Uberis (Pedersen et al. 2003) and intra-udder infusion of endotoxin (LPS) derived from the cell wall of E.Coli (Lehtolainen et al., 2004)

Technical studies

Type of milk MAA Threshold SCC Threshold Sensitivity Specificity Type of mastitis Reference
Quarter >16,4mg/L 90,6% 98,3% Subclinical Safi et al. 2009
Quarter >130 89,6% 72,0% Subclinical Safi et al. 2009
Composite 100 96,6% 57,9% Major pathogen Jaeger et al. 2016
Composite 3,9μg/mL 84,7% 96,6% Major pathogen Jaeger et al. 2016
Composite 3,9μg/mL 100 82,0% 98,0% Major pathogen Jaeger et al. 2016
Tank 20,78 ng/mL <200> 97,3% 46,7% Subclinical Taghdiri, 2018

Two kit formats are available depending on the analytical needs of the laboratory:

  • TM-900 kit for 800 tests,
  • TP-8072 kit for 80 tests.
Compatible with most ELISA microplate readers
5

ТЕХНИЧЕСКОЕ ОБСЛУЖИВАНИЕ И ПОДДЕРЖКА

Обслуживание клиентов всегда было приоритетом для Bentley Instruments. Мы гарантируем нашим клиентам оперативную помощь для достижения оптимальной производительности.

Чтобы гарантировать высочайший уровень производительности, наша команда технических специалистов занимается установкой, обучением и диагностикой удаленно и на месте.

Платформа FreshDesk доступна при регистрации и предоставляет вам доступ к нашей платформе электронного обслуживания: сервису электронных билетов, где вы можете задать нашим инженерам вопросы о ваших проблемах, техническим базам данных (история оборудования, технические примечания, руководства...), инструментам диагностики (проблема/решение), всемирной сети инженеров-технологов и послепродажного обслуживания. сервис для получения быстрой и интерактивной помощи в вашем распоряжении в любое время.

BENTLEY INSTRUMENTS EU

ZA Brunehaut 840 rue Curie
62161 Maroeuil - France
+33 (0)2 85 52 90 73
Fax : +33 (0)3 20 09 87 12
info@bentleyinstruments.ru

BENTLEY INSTRUMENTS INC.

4004 Peavey Rd Chaska
Minnesota 55318 - USA
+1 952 448 7600
+1 952 368 3355
info@bentleyinstruments.com

BENTLEY INSTRUMENTS RUS

4004 Peavey Rd Chaska
Minnesota 55318 - USA
+1 952 448 7600
+1 952 368 3355
info@bentleyinstruments.com